XKMSD遂道专用分支防水接线盒

当前位置:

产品中心

XKMSD遂道专用分支防水接线盒

XKMSD遂道专用分支防水接线盒

如果您有任何问题可以联系我们!
联系我们
一、典型应用 Typicala pplications
1、遂道系统专用
2、建筑照明、路灯、高层坚井线连接
3、高层建筑坚井电缆户外架空线、电缆沟工厂动力供电主缆
1. Streetlight system
2. Architectural lighting, streetlight and high-rise shaft line connection
3. High-rise shaft cable, outdoor overhead line, troughing, main cable for factory power supply

① 首先剥去电缆外护套皮
外护套皮剥去的长度应小于电缆盒内腔的有效长度。

First, peel off the outer sheath of cable
Peeled length of outer sheath should be smaller than the effective length of inner
chamber of cable box.


订货号Order no .110733
② 不需剥去的电缆的绝缘皮,接头完全绝缘;不需截断主电缆,可在电缆任意位置做分支。
It is unnecessary to peel off the insulating sheath of cable, the joint is fully insulated; it is unnecessary to cut off the main cable, we can make branch at any position of cable.
③ 按照下列步骤安装绝缘穿刺线夹
Install the insulation piercing connector according to the following procedures
1.将断面整齐的支线插入分支器盖套
Insert branch line into the casing cover of connector
2.将分支器固定于主干线连接处,然后用力拧紧力矩螺母
Fix clamp on the joint of main line,then twist firmly by hand.
3. 用六角套筒扳手垂直拧紧力矩螺母至螺帽断开为止
Vertically twist moment screw to break screw cap with hexagonal set spanner.
4. 继续用力旋紧螺母直到顶端断裂脱落
Vertically twist moment screw to break screw cap with hexagonal set spanner.
④ 安装后的遂道分支防水接线盒在分支中呈等距离状分布。
Tunnel branching waterproof junction box after installation presents equidistance distribution among the branches.


订货号Order no .110734


订货号Order no .110735
二、安装方法 Installation methods

        遂道分支防水接线盒均使用膨胀螺栓固定于隧道壁上,在隧道侧壁的水平位置上,孔深40mm,将 M6 膨胀螺栓塞入孔中,套上穿剌线夹盒安装支架,然后将M6螺母拧紧。

        Tunnel branching waterproof junction box is fixed on the tunnel wall in horizontal position with expansion bolts, hole depth is 40mm, set expansion bolts of M6 into the hole, install the supporting rack of piercing connector box, then tighten the M6 nuts.

安装固定架
Installation of fixed mount
订货号Order no .110736
订货号Order no .110737
三、适用说明 Application description
   
将支线剥去一定长度的外护套,穿过尼龙防水头。
Peel off a certain length of the outer sheath of branch line, and put through the nylon waterproof joint.
根据具体情况、需求安装线夹,注意线夹在带电安装过程中应戴
上绝缘手套,每个线夹位置应错开,以便下一步安装。
Install the connectors according to actual conditions and
remands, pay attention to wearing insulating gloves when
installing the connectors under live condition, connectors
should be staggered from each other, make it convenient for next mounting procedure.
将电缆沿橡胶开口处卡入,并放在防水盒两端,橡胶开口处应调
整至与防水盒上下盖接缝处平行!
Set the cable along the rubber opening, place it on two sides of waterproof box, rubber opening should be parallel with the joining part of upper and lower covers of waterproof box!
合上盖子,将螺丝拧紧(注:安装6个螺丝时应初步每个进行固定
再进行拧紧)。再顺时针拧紧支线处防水尼龙头。
Close the cover, tighten the screws (note: when mounting the 6 screws, shall fix each of them preliminarily, then tighten).

点击
隐藏

微信
咨询


扫一扫,了解更多!

电话
咨询

0577-6161 6111
客服热线